76 Upgrade MPT ODU to MPT ODU L1 LAG
port
76.1 Purpose
This chapter provides the procedure to upgrade an Out-of-Service MPT-HC/
MPT-XP/9558HC (MPT ODU) radio hop to an MPT ODU configured as the L1 LAG
Master Port.
See the 9500 MPR Hardware Installation and Replacement Manual for information
about connecting fiber cable and installing SFPs.
76.2 General
This upgrade procedure provides general steps and the sequence required to
upgrade an MPT ODU radio interface supported on an MPTACC card to an
MPT ODU radio interface supported on an P8ETH card and configured as the L1
LAG Master Port.
The L1 LAG Master Port must be located in P8ETH card Ethernet port 5 or 7.
The number of possible radio configurations precludes covering all possible radio
configurations.
MPT ODU connected to an P8ETH card requires power provided by one of the
following methods:
MPT Power Unit
MPT Extended Power Unit (required for MPT-XP)
Power Injector Card
Power Injector Box
Direct connection to office power
MPTACC card
A site survey and site documentation must be provided to ensure that facilities that
are not associated with the upgrade MPT ODU radio direction are not impacted by
this upgrade procedure.