Provision Ethernet Ring Protection (ERP)
572
WebEML User Manual
a. If yes, repeat steps 4 and 5 to create a second ERP Instance.
See Figure 384 for an example of two ERP Instances provisioned.
b. If no, go to step 7.
Figure 385 Two ERP Instances created
7. Select ERP Instance to provision Wait-to-Restore Time and Guard Timer.
8. Ring Node RPL Owner?
a. If yes, go to step 9.
b. If no, go to step 10.
9. From the Wait-to Restore Time drop-down menu, select 1 to 12 minutes.
10. In the Guard Timer field, enter Guard Timer duration; 10 to 2000 ms.
11. Click Apply.
12. Repeat steps 7 and 11 to provision Wait-to-Restore Time and Guard Timer on
second ERP Instance if applicable.
Release 7.0.0 3DB 19286 ACAA Issue 01