WebEML User Manual
Figure 681 SDHACC configuration screen
i. Put a check mark in the Port Status box to enable the STM-1.
ii. Set the Auto Laser Shutdown: Enabled/Disabled ForcedOn/Disabled
ForcedOff. This field will appear only if the Settings tab-panel of the STM-1
unit the optical SFP has been selected.
iii. Enable the J0, if required, by selecting one of the two modes
(SixteenBytesFrame/OneRepeatedByte) and in the Expected Receiving
Value field enter the expected value. Note: byte J0 is only read, no
Regeneration section Termination is done.
iv. Enter the Flow ID (range: 2 to 4080). Warning: the flow id must be unique
in the MPR network.
v. Select the Jitter Buffer Depth: High/Low.
vi. Service profile: fixed to SDH2SDHClock Source: The purpose of TMN Clock
Source provisioning is to select the mode, that will be used to sync STM-1
data to the node Synchronization source.
vii. Differential: to sync the output to NE Synchronization source.
Release 7.0.0 3DB 19286 ACAA Issue 01