WebEML User Manual High-level procedure for DS3 deprovisioning
71
5 High-level procedure for DS3
deprovisioning
5.1 Purpose
This chapter provides a high-level procedure for deprovisioning DS3 facilities and
equipment.
5.2 Procedure
1. Disable performance monitoring on the equipment you need to deprovision.
2. Select action.
a. To deprovision DS3 cross-connect, go to step 3.
b. To deprovision DS3 port, go to step 4.
c. To deprovision DS3 P2E3DS3 card, go to step 5.
3. Deprovision DS3 cross-connect: see Deprovision cross connections.
4. Deprovision DS3 port:
a. See Deprovision cross connections to deprovision DS3 cross-connect
associated with DS3 port.
b. See Deprovision equipment ports to deprovision DS3 port.
5. Deprovision DS3 P2E3DS3 card:
a. See Deprovision cross connections to deprovision DS3 cross-connects
associated with P2E3DS3 card.
b. See Deprovision equipment ports to deprovision DS3 ports associated with
P2E3DS3 card.
c. See Disable equipment to disable P2E3DS3 card.
Release 7.0.0 3DB 19286 ACAA Issue 01