Configure radio parameters
786
WebEML User Manual
Provision the radio protection scheme before provisioning MPT-HLx/MPT ODU radio
channel parameters. If MPT-HLx/MPT ODU radio parameters are provisioned before
the protection scheme, unexpected radio alarms may be reported on the radio
channel. To clear these unexpected radio alarms, a system restart is required.
59.2.1 Monodirectional links
For the management of monodirectional radio links, different configurations are
needed on each side of the link. Table 6describes the configuration requirements.
Note: Most procedures are shown using the MSS-8 screen. However, the operation is
similar for all MSS shelves.
Note: All supported channel plans do not support all possible radio profile combinations. For
a table of supported profiles per radio channel plan, see the 9500 MPR Product Information
Manual Engineering Specifications section.
Table 6 Configurations in monodirectional links
Parameter Tx only node Rx only node
ATPC Should not be enabled; cannot
work
Should not be enabled; cannot
work
ACM Should not be enabled; cannot
work
Should not be enabled; cannot
work
L1 LAG Should not be enabled; cannot
work
Should not be enabled; cannot
work
Ring Should not be enabled; cannot
work
Should not be enabled; cannot
work
Radio PM Should not be enabled; it works
on the Rx side
Can be enabled
Link identifier Should not be enabled; it works
on the Rx side
Can be enabled
PPP Must be disabled (otherwise a
PPP Failure alarm will be raised)
Must be disabled (otherwise a
PPP Failure alarm will be raised)
No Rx Radio Alarms alarm
profile
Must be configured in the radio
panel (otherwise all the Rx Radio
alarms will be raised)
—