WebEML User Manual Administer external alarm points on an MSS-1 or
Enhanced Fan card
117
16 Administer external alarm points on an
MSS-1 or Enhanced Fan card
16.1 Purpose
The procedure in this chapter provides instructions to administer the external alarm
points supported by the MSS-1 unit and the Enhanced Fan card.
16.2 Prerequisites
For MSS-1: The MSS-1 must be active before the external alarm points can be
provisioned.
For the Enhanced Fan card: The Enhanced Fan card must be enabled in MSS-8 slot
9 before the external alarm points can be provisioned.
16.3 Overview
The MSS-1 and Enhanced Fan card support four external alarm inputs and three
alarm outputs.
Each external alarm input is provisionable; alarm active low or active high, and user
label.
The alarm outputs do not require provisioning by the operator: they operate alarm
LEDs on the shelf.