View alarms
250
WebEML User Manual
The alarms have a different color according to their severity and their state.
Critical: Red
Major: Orange
Minor: Yellow
Warning: Blue
Indeterminate: White
Cleared: Green
Within the tab panel, each alarm is provided with the following information:
Time & Date: date and time of the alarm. The format of date and time is yyyy/
mm/dd hh:mm:ss.
Probable cause: name of the probable cause of the alarm.
Alarm Type: alarm class (TRS = Transmission Alarm – alarm not created inside
the equipment, but generated by a connected equipment or due to transmission/
propagation problems; EQUIPMENT: alarm inside of the equipment).
Friendly Name: object of the equipment where the alarm occurred.
Severity: alarm severity.
Add Text: for some alarms, additional text regarding the alarm.
Specific problem: for some alarms, additional information is provided about the
involved resource (for instance, when a threshold alarm is raised, it states the
specific threshold exceeded)
The Alarm Monitor menu bar has the following options available:
•File
•Filters
•Help
The File Menu has the following options available:
Save Log for selected NE: This option saves a file with one of the two global
lists of each NE. Select the global list of a specific NE, open the Save History
menu for the selected NE and enter filename and relevant directory in the
opening window.
Load Log to selected NE: This option displays the global list of a certain NE
previously saved.
Remove selected NE: This option removes the selected NE from the list of NEs
monitor by the Alarm Monitor.