Provision cross connections
380
WebEML User Manual
7. Enter the destination MAC address where the Ethernet flow will be terminated in
the MAC Address field.
8. On the ETH-RING pop-up, click >>.
9. Repeat steps 4 through 8 to provision additional ETH to Ring cross-connections
on this ERP Instance.
10. On the ETH-RING pop-up, click OK.
11. On the Cross Connection screen, click Apply.
12. From the Connections tab, verify the ETH-RING cross-connections were
entered correctly.
To provision a Ring to Ring Cross Connection
1. Double left-click Ring port icon.
RING-RING pop-up displays. See Figure 211.
Note: The first two digits of the destination MAC address for unprotected ports must be set
to ‘unicast’ or ‘00’. The first two digits of the destination MAC address for 1+1 protected and
L1 LAG ports must be set to ‘multicast’ or ‘01’. The first two digits of the destination MAC
address for all ERPS ring nodes must be set to ‘unicast’ or ‘00’
Release 7.0.0 3DB 19286 ACAA Issue 01