WebEML User Manual Use the Provisioning Tool
921
10. If required, enable the SSM.
11. Click on the Apply button. The Apply button saves the configuration.
12. Repeat the previous steps to configure another LAG or click on the Next
button.
When the LAG is configured, the radio icons for the radios in the LAG show an
L symbol in the MSS Subrack panel: ( )
2. Click on the Next button. The next screen to open depends on the configuration.
To configure the XPIC configuration screen
1. Perform step 2 to configure 1+0 XPIC or step 3 to configure 1+1 XPIC.
2. To configure 1+0 XPIC:
i. Drag with the mouse from an MPT icon to another MPT icon. The letter V
means MPT set with Vertical polarization; the letter H means MPT set with
Horizontal polarization. The two MPT must have different polarization.
ii. Put a check mark and click on OK. See Figure 692.
Note: The PPP RF channel for TMN is managed here at LAG level and not at radio level.
In case of 2 parallel LAG groups, the PPP rules are the same as for Nx(1+0) and Nx(1+1).
The TMN RF option must be disabled on all links except one. The TMN PPP traffic may
use the other links for protection, when the enabled link is failed. This protection may
require waiting for the destination MAC address to age out of the forwarding table before
recovering.
Note: The SSM is managed here at LAG level and not at radio level.
Note: The MPT polarization must be configured on the MPT configuration
screen.
Release 7.0.0 3DB 19286 ACAA Issue 01