Upgrade MPT ODU to MPT ODU L1 LAG port
1070
WebEML User Manual
14. If MPTACC PFoE/SMA connector is the power source for the MPT ODU, the
Ethernet/coax cable remains connected and will be used to power the
MPT ODU.
15. If MPTACC PFoE is the power source for the MPT ODU, perform one of the
following:
a. Disable the power source. Then provision the power source for PFoE. See
Configure radio parameters for a detailed procedure to provision MPT ODU
power scheme.
b. Unplug and reinsert the PFoE Ethernet cable on the MPTACC card.
16. Create L1 LAG port. See Administer L1/L2 radio and L2 Ethernet LAG ports for
a detailed procedure to create L1 LAG port.
17. Add MPT ODU radio interface to L1 LAG port. See Administer L1/L2 radio and
L2 Ethernet LAG ports for a detailed procedure to create L1 LAG port.
18. Verify that the radio direction is alarm free.
19. Verify that the radio direction is error free and operating as expected.
Note: To complete the upgrade to MPT ODU L1 LAG Port, this procedure must
be performed on both ends of the radio hop.
Release 7.0.0 3DB 19286 ACAA Issue 01