Release : 1.1f 259 / 985
Super Micro Intelligent Switch Command Line Interface User Guide
10.12 dot1x control-direction
This command configures port control direction and the no form of the command sets the
authenticator port control direction to both.
dot1x control-direction {in | both}
no dot1x control-direction
Syntax Description
in - Authentication control is imposed only on the incoming packets
both - Authentication control is imposed on both incoming and outgoing packets
Mode
Interface Configuration Mode
Defaults
both
Example
SMIS(config-if)# dot1x control-direction in
Related Command
show dot1x - Displays dot1x information

Table of Contents