Release : 1.1f 964 / 985
Super Micro Intelligent Switch Command Line Interface User Guide
36.3 lldp holdtime-multiplier
This command helps to configure the time to live of LLDP information. The LLDP devices hold the
received LLDP information for the time advertised as time to live information.
This time to live value is calculated as below:
time to live = holdtime multiplier X transmit interval
This command helps to configure this holdtime multiplier. The no form of this command resets
this hold time multiplier to its default 4.
lldp holdtime-multiplier <value(2-10)>
no lldp holdtime-multiplier
Syntax Description
holdtime-multiplier – any number between 2 to 10
Mode
Global Configuration Mode
Defaults
4
Example
SMIS(config)# lldp holdtime-multiplier 5
Related Commands
show lldp – Displays the LLDP feature information.