Release : 1.1f 353 / 985
Super Micro Intelligent Switch Command Line Interface User Guide
15.15 switchport pvid
This command configures the PVID (VLAN Identifier) that would be assigned to untagged/priority-
tagged frames. The no form of this command sets the PVID to the default value.
switchport pvid <vlan-id(1-4069)>
no switchport pvid
Mode
Interface Configuration Mode
Defaults
vlan-id - 1
Example
SMIS(config-if)# switchport pvid 3
Related Command
show vlan port config - Displays the VLAN related parameters specific for ports