25.18 timers basic
This command sets update, route age and garbage collection timers. The no form of the
command sets update, route age and garbage collection timers to the default values.
timers basic <update-value (10-3600)> <routeage-value (30-500)>
<garbage-value (120-180)>
no timers basic
Syntax Description
update-value - Interval Time Between Updates
routeage-value - Time after which the entry is put into garbage collect interval
garbage-value - Interval before deleting an entry after not hearing it
Mode
Interface Configuration Mode
update-value - 30
routeage-value - 180
Defaults
garbage-value - 120
Example
SMIS(config-if)# timers basic 20 40 150
The advertisements of garbage-value entry is set to INFINITY, while sending to others.