Release : 1.1f 957 / 985
Super Micro Intelligent Switch Command Line Interface User Guide
35.3 link-status-tracking group - interface
This command adds the interfaces as either downstream or upstream interfaces to the link status
tracking groups.
The no form of this command removes the interfaces from the link status tracking groups.
link-status-tracking group <short(1-1024)> {upstream | downstream}
no link-status-tracking
Syntax Description
group – Any number between 1 to 1024
upstream – configure this interface as the upstream interface for the given group
downstream - configure this interface as the downstream interface for the given group
Mode
Interface Configuration Mode
Example
SMIS(config-if)# link-status-tracking group 1 upstream
Related Commands
show link-status-tracking – Displays the link status tracking feature information.