EasyManua.ls Logo

Microsemi SmartFusion2 - Table 385 RPKT; Table 387 RMCA

Microsemi SmartFusion2
829 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ethernet MAC
UG0331 User Guide Revision 15.0 418
Table 385 • RPKT
Bit Number Name Reset Value Description
[31:18] Reserved 0x0 Reserved
[17:0] RPKT 0x0 Receive packet counter: Incremented for each frame received
packet (including bad packets, all the unicast, broadcast, and
multicast packets).
Table 386 • RFCS
Bit Number Name Reset Value Description
[31:12] Reserved 0x0 Reserved
[11:0] RFCS 0x0 Receive FCS error counter: Incremented for each frame received
that has an integral 64 to 1518 length and contains a FCS error.
Table 387 • RMCA
Bit Number Name Reset Value Description
[31:18] Reserved 0x0 Reserved
[17:0] RMAC 0x0 Receive multicast packet counter: Incremented for each multicast
good frame of lengths smaller than 1518 (non VLAN) or 1522
(VLAN) excluding the broadcast frames. This does not include
range, length errors.
Table 388 • RBCA
Bit Number Name Reset Value Description
[31:22] Reserved 0x0 Reserved
[21:0] RBCA 0x0 Receive broadcast packet counter: Incremented for each
Broadcast good frame of lengths smaller than 1518 (non VLAN) or
1522 (VLAN) excluding the multicast frames. This does not look at
range/length errors.
Table 389 • RXCF
Bit Number Name Reset Value Description
[31:18] Reserved 0x0 Reserved
[17:0] RXCF 0x0 Receive control frame packet counter: Incremented for each MAC
control frame received (PAUSE and Unsupported).
Table 390 • RXPF
Bit Number Name Reset Value Description
[31:12] Reserved 0x0 Reserved
[11:0] RXPF 0x0 Receive PAUSE frame packet counter: Incremented each time a
valid PAUSE MAC control frame is received.