3 Spectrum Analyzer Mode
3.4 Occupied BW Measurement
–
Trace 1: Visible, being updated, in Clear/Write, with Normal detector auto
selected
–
Trace 2: Visible, being updated, in Clear/Write, being written to with a math
function
–
Trace 3: Visible, not updating, data was taken in Max Hold, with the peak
detector auto selected
–
Trace 4: Blanked, not updating, data was taken with Averaging turned on,
Sample detector manually selected
–
Trace 5: Visible, not updating, data was taken in Min Hold with Negative Peak
detector auto selected
–
Trace 6: Blanked, not updating, in Clear/Write, with Normal detector manually
selected
Trace Annotation
When Trace Annotation (see Display) is ON, each non-blanked trace is labeled on the
trace with the detector used to take it, unless a Trace Math function is on for that
trace, in which case it is labeled with the "Math Function" on page 1743.
The detector labels are:
NORM
Normal
PEAK
Peak
SAMP
Sample
NPEAK
Negative Peak
RMS
Average detector with Power Average (RMS)
LG AVG
Average detector with Log-Pwr Average
VAVG
Average detector with Voltage Average
QPEAK
Quasi Peak
EMI AVG
EMI Average
RMS AVG
RMS Average
The trace math labels are:
PDIF
Power Difference
PSUM
Power Sum
LOFF
Log Offset
LDIF
Log Difference
848 Spectrum Analyzer Mode User's &Programmer's Reference