3 Spectrum Analyzer Mode
3.7 Burst Power Measurement
3.7.10.1 Trace Control
The controls on this tab allow you to select display of the Max Hold trace and the
Min Hold Trace.
Max Hold Trace
Enables you to select visible/invisible Max Hold Trace.
Remote
Command
:DISPlay:TXPower:WINDow[1]:TRACe:MAXHold[:STATe] ON | OFF | 1 | 0
:DISPlay:TXPower:WINDow[1]:TRACe:MAXHold[:STATe]?
Example
:DISP:TXP:WIND:TRAC:MAXH ON
:DISP:TXP:WIND:TRAC:MAXH?
Couplings Selecting [:SENSe]:TXPower:AVERage:TYPE MAXimum forces this parameter to ON
Preset
OFF
State Saved Yes
Range
ON|OFF
Backwards
Compatibility
SCPI
:DISPlay:TXPower:VIEW[1]:WINDow[1]:TRACe:MAXHold[:STATe]
Min Hold Trace
Enables you to select visible/invisible Min Hold Trace.
Remote
Command
:DISPlay:TXPower:WINDow[1]:TRACe:MINHold[:STATe] ON | OFF | 1 | 0
:DISPlay:TXPower:WINDow[1]:TRACe:MINHold[:STATe]?
Example
:DISP:TXP:WIND:TRAC:MINH ON
:DISP:TXP:WIND:TRAC:MINH?
Couplings Selecting [:SENSe]:TXPower:AVERage:TYPE MINimum forces this parameter to ON
Preset
OFF
State Saved Yes
Range
ON|OFF
Backwards
Compatibility
SCPI
:DISPlay:TXPower:VIEW[1]:WINDow[1]:TRACe:MINHold[:STATe]
Spectrum Analyzer Mode User's &Programmer's Reference 1351