This value is clipped to keep Abs Start/Stop Freq within the available frequency
range. This clipping applies even when OB Start Freq, OB Stop Freq or Offset Side is
changed.
Remote
Command
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STARt <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STARt?
Example
:SPUR:OFFS:FREQ:STAR 9 kHz, 150 kHz, 30 MHz, 1GHz, 1.5 GHz, 1.5 GHz, 1.5 GHz,
1.5 GHz,1.5 GHz,1.5 GHz, 1.5 GHz, 1.5 GHz, 1.5 GHz,1.5 GHz,1.5 GHz,1.5
GHz,1.5 GHz,1.5 GHz,1.5 GHz,1.5 GHz
:SPUR:OFFS:FREQ:STAR?
Preset 10 MHz, 20 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30
MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz
State Saved Saved in instrument state
Min/Max -80 MHz/SA Max Freq - 10Hz (Hardware Dependent)
Offset Stop Freq
Sets the range frequency as offset from one of operating band edges. This
parameter can send up to 20 values. The location in the list sent corresponds to the
range the value is associated with.
The location of where the stop frequency occurs in the list sent to the measurement
corresponds to the range the value is associated with.
When sending the remote command, missing values are not permitted. If you want
to change values 2 and 6, then you must send all values up to 6. Subsequent values
will remain as they were. The query always returns 20 values.
This parameter is coupled with either "Abs Start Freq" on page 1451 or "Abs Stop
Freq" on page 1451 using the coupling equations shown in "Enabled" on page 1450.
This value is clipped to keep Abs Start/Stop Freq inside the available frequency
range. This clipping applies even when OB Start Freq, OB Stop Freq or Offset Side is
changed.
Remote
Command
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STOP <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STOP?
Example
:SPUR:OFFS:FREQ:STOP 150kHz, 30MHz, 1GHz, 2.1GHz, 2.1GHz, 2.1774GHz, 2.18GHz,
12.75GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz,
2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz
:SPUR:OFFS:FREQ:STOP?
Preset 20 MHz,30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30
MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz
Spectrum Analyzer Mode User's &Programmer's Reference 1453

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)