3 Spectrum Analyzer Mode
3.8 Spurious Emissions Measurement
This value is clipped to keep Abs Start/Stop Freq within the available frequency
range. This clipping applies even when OB Start Freq, OB Stop Freq or Offset Side is
changed.
Remote
Command
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STARt <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STARt?
Example
:SPUR:OFFS:FREQ:STAR 9 kHz, 150 kHz, 30 MHz, 1GHz, 1.5 GHz, 1.5 GHz, 1.5 GHz,
1.5 GHz,1.5 GHz,1.5 GHz, 1.5 GHz, 1.5 GHz, 1.5 GHz,1.5 GHz,1.5 GHz,1.5
GHz,1.5 GHz,1.5 GHz,1.5 GHz,1.5 GHz
:SPUR:OFFS:FREQ:STAR?
Preset 10 MHz, 20 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30
MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz
State Saved Saved in instrument state
Min/Max -80 MHz/SA Max Freq - 10Hz (Hardware Dependent)
Offset Stop Freq
Sets the range frequency as offset from one of operating band edges. This
parameter can send up to 20 values. The location in the list sent corresponds to the
range the value is associated with.
The location of where the stop frequency occurs in the list sent to the measurement
corresponds to the range the value is associated with.
When sending the remote command, missing values are not permitted. If you want
to change values 2 and 6, then you must send all values up to 6. Subsequent values
will remain as they were. The query always returns 20 values.
This parameter is coupled with either "Abs Start Freq" on page 1451 or "Abs Stop
Freq" on page 1451 using the coupling equations shown in "Enabled" on page 1450.
This value is clipped to keep Abs Start/Stop Freq inside the available frequency
range. This clipping applies even when OB Start Freq, OB Stop Freq or Offset Side is
changed.
Remote
Command
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STOP <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>,
<freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>, <freq>
[:SENSe]:SPURious[:RANGe][:LIST]:OFFSet:FREQuency:STOP?
Example
:SPUR:OFFS:FREQ:STOP 150kHz, 30MHz, 1GHz, 2.1GHz, 2.1GHz, 2.1774GHz, 2.18GHz,
12.75GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz,
2.5GHz, 2.5GHz, 2.5GHz, 2.5GHz
:SPUR:OFFS:FREQ:STOP?
Preset 20 MHz,30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30
MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz, 30 MHz
Spectrum Analyzer Mode User's &Programmer's Reference 1453