3 Spectrum Analyzer Mode
3.3 Channel Power Measurement
be able to return easily to your original Basic View, you can save your edited View as
a “User View”.
Save Layout as New View
Saves your new View as a User View. An alpha keyboard appears, which lets you
name your new View; the default is the old View name plus a number.
Remote
Command
:DISPlay:VIEW:ADVanced:NAME <alphanumeric>
Example
:DISP:VIEW:ADV:NAME “Baseband”
Creates a new View named Baseband from the current View, and selects it as the current View
Notes <alphanumeric> is case insensitive; you can specify mixed case, however the name will be
evaluated on a single case
If <alphanumeric> name already exists as a View, the error message “-224, Illegal parameter value;
View <alphanumeric> already exists” is generated
If the display is disabled (via :DISP:ENAB OFF) then the error message “-221, Settings conflict; User
View SCPI cannot be used while Display is disabled” is generated
Re-Save User View
You can re-edit a User View; if you make changes, then an asterisk will appear next
to the User View’s name. You can then tap Re-Save User View to save it back to its
existing name, or Save Layout as New View to add another, new User View.
This is a front panel function only, there is no remote command available to perform
this function. To do this remotely, you must first perform Save Layout as New View,
then delete the old User View and rename the new one with the name of the View
you just deleted.
Rename User View
You can rename the current View by giving it a new unique name. Only User Views
can be renamed, if the current View is a Predefined View, an error occurs.
Remote
Command
:DISPlay:VIEW:ADVanced:REName <alphanumeric>
Example
:DISP:VIEW:ADV:REN “Baseband”
Notes <alphanumeric> is case insensitive; you can specify mixed case, however the name will be
evaluated on a single case
If the <alphanumeric> specifying the new name is already present in the list of View names, the
error message “-224, Illegal parameter value; View <alphanumeric> already exists” is generated
If the current View is a Predefined View, the error message “-224, Illegal parameter value; Cannot
Spectrum Analyzer Mode User's &Programmer's Reference 619

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)