3 Spectrum Analyzer Mode
3.8 Spurious Emissions Measurement
Adjusting the EMC Std of any Mode that supports Global settings, while Global EMC
Std is ON modifies the Global EMC Std.
When Global EMC Std is switched OFF, the EMC Std of the current Mode remains
unchanged, but now the EMC Std of each Mode is once again independent. When
Mode Preset is pressed while Global EMC Std is ON, Global EMC Std is preset to the
preset EMC Std of the current Mode.
This function resets to OFF when "Restore Defaults" on page 2037 is pressed, or
when System, Restore Defaults, All Modes is pressed.
Remote Command
:INSTrument:COUPle:EMC:STANdard ALL | NONE
:INSTrument:COUPle:EMC:STANdard?
Example
:INST:COUP:EMC:STAN ALL
:INST:COUP:EMC:STAN?
Dependencies Only available if Option EMC is installed
Preset Set to OFF on Global Settings, Restore Defaults and System, Restore Defaults, All Modes
Range
ALL | NONE
Global Limit Lines (Freq and Amptd)
When this control is set to ALL, the current Mode’s Limit Line is copied into the
Global Limit Lines, and from there to all Modes that support Global settings and use
Global Limit Lines, so you can switch between any of these Modes and the Limit
Lines remain unchanged.
Adjusting the Limit Lines of any Mode that supports Global Settings, while Global
Limit Lines is ALL, modifies the Global Limit Lines.
When Global Limit Lines is set to NONE, the Limit Lines of the current Mode are
unchanged, but now the Limit Lines of each Mode are once again independent.
When Mode Preset is pressed while Global Limit Lines is ALL, Global Limit Lines is
preset to the preset Limit Lines of the current Mode.
This function is reset to NONE when "Restore Defaults" on page 2037 is pressed, or
when System, Restore Defaults, All Modes is pressed.
Remote
Command
:INSTrument:COUPle:LLINe ALL | NONE
:INSTrument:COUPle:LLINe?
Example
:INST:COUP:LLIN ALL | NONE
:INST:COUP:LLIN?
Preset Set to OFF on Global Settings, Restore Defaults and System, Restore Defaults, All Modes
Range
ALL | NONE
1492 Spectrum Analyzer Mode User's &Programmer's Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals