EasyManuals Logo

Keysight x-series User Manual

Keysight x-series
2852 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #871 background imageLoading...
Page #871 background image
3 Spectrum Analyzer Mode
3.5 ACP Measurement
3.5 ACP Measurement
ACP is a measurement of the amount of interference, or power, in an adjacent
frequency channel. The results are displayed as a bar graph or as spectrum data,
with measurement data at specified offsets.
Measurement Commands
The general functionality of "CONFigure" on page 2753, "INITiate" on page 2754,
"FETCh" on page 2754, "MEASure" on page 2756, and "READ" on page 2755 are
described in the section SCPI Operation and Results Query in the topic
Programming the Instrument.
The following measurement commands and queries are used to configure the
measurement:
:INITiate:ACPower
Initiates a trigger cycle for the ACPower measurement,
but does not return any data. You must then use
:FETC:ACP[n]? to retrieve data
Does not change any measurement settings
:CONFigure?
Returns the long form name of current measurement, in
this case, ACPower
:CONFigure:ACPower
Selects ACP measurement with Meas Setup settings in
preset state same as "Meas Preset" on page 1013
:CONFigure:ACPower:NDEFault
Selects ACP measurement without affecting settings
The following queries are used to retrieve the results:
:FETCh:ACPower?
Retrieves the data specified by n
:MEASure:ACPower
[n]?
Switches to ACP measurement, restores default values, starts the
measurement, then retrieves the data specified by n
:READ:ACPower[n]?
Starts the measurement, then retrieves the data specified by n
Remote Command Results
The following table describes the results returned by the :FETCh, :MEASure, and
:READ queries listed above, according to the index value n.
n Results Returned
1, or not
specified
Dependent on Mode, "Meas Method" on page 970, "Power Ref" on page 1056 , and "Measurement Type"
on page 1055
See "Measurement Results for n = 1, or no Index Specified" on page 874
2 Dependent on "Measurement Type" on page 1055. See "Measurement Results for n = 2" on page 877
3 Dependent on Mode and "Measurement Type" on page 1055. See "Measurement Results for n = 3" on
Spectrum Analyzer Mode User's &Programmer's Reference 871

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)