3 Spectrum Analyzer Mode
3.8 Spurious Emissions Measurement
3.8.4 BW
There is no BW functionality in this measurement.
3.8.5 Display
Opens the Display menu, which lets you configure display items for the current
Mode, Measurement View or Window.
3.8.5.1 Meas Display
Contains controls for setting up the display for the current Measurement, View, or
Window.
Center Frequency On/Off
Turns the display of Center Frequency on the Meas Bar On or Off.
Remote
Command
:DISPlay:SPURious:FREQuency:CENTer[:STATe] ON | OFF | 1 | 0
:DISPlay:SPURious:FREQuency:CENTer[:STATe]?
Example
:DISP:SPUR:FREQ:CENT ON
:DISP:SPUR:FREQ:CENT?
Preset
ON
State Saved Yes
3.8.5.2 Annotation
Contains controls for setting up the annotation for the current Mode or
Measurement.
Graticule
Turns the display graticule On or Off for all windows with graticules in all
measurements in the current Mode. Also turns the graticule Y-Axis annotation on
and off.
Remote
Command
:DISPlay:GRATicule[:STATe] OFF | ON | 0 | 1
:DISPlay:GRATicule[:STATe]?
Example
:DISP:GRAT OFF
1406 Spectrum Analyzer Mode User's &Programmer's Reference