EasyManuals Logo

Keysight x-series User Manual

Keysight x-series
2852 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2707 background imageLoading...
Page #2707 background image
9 Programming the Instrument
9.1 List of Supported SCPI Commands
CALCulate:FPOWer:POWer[1,2,…,999]:CONFigure
CALCulate:FPOWer:POWer[1,2,…,999]:DEFine?
CALCulate:FPOWer:POWer[1,2,…,999]:FETCh?
CALCulate:FPOWer:POWer[1,2,…,999]:INITiate
CALCulate:FPOWer:POWer[1,2,…,999]:READ?
CALCulate:FPOWer:POWer[1,2,…,999]:READ1?
CALCulate:FPOWer:POWer[1,2,…,999]:READ2?
CALCulate:FPOWer:POWer[1,2,…,999]:RESet
CALCulate:LIMit[1]|2|…|6:CLEar
CALCulate:LIMit[1]|2|…|6:CONTrol[:DATA]
CALCulate:LIMit[1]|2|…|6:CONTrol:POINts?
CALCulate:LIMit[1]|2|…|6:FAIL?
CALCulate:LIMit[1]|2|…|6:LOWer[:DATA]
CALCulate:LIMit[1]|2|…|6:LOWer:POINts?
CALCulate:LIMit[1]|2|…|6:UPPer[:DATA]
CALCulate:LIMit[1]|2|…|6:UPPer:POINts?
CALCulate:LLINe[1]|2|…|6:AMPLitude:CMODe:RELative
CALCulate:LLINe[1]|2|…|6:AMPLitude:INTerpolate:TYPE
CALCulate:LLINe[1]|2|…|6:BUILd
CALCulate:LLINe[1]|2|…|6:COMMent
CALCulate:LLINe[1]|2|…|6:CONTrol:INTerpolate:TYPE
CALCulate:LLINe[1]|2|…|6:COPY
CALCulate:LLINe[1]|2|…|6:DELete
CALCulate:LLINe[1]|2|…|6:DESCription
CALCulate:LLINe[1]|2|…|6:DISPlay
CALCulate:LLINe[1]|2|…|6:FAIL?
CALCulate:LLINe[1]|2|…|6:FREQuency:CMODe:RELative
CALCulate:LLINe[1]|2|…|6:MARGin
CALCulate:LLINe[1]|2|…|6:MARGin:STATe
CALCulate:LLINe[1]|2|…|6:OFFSet:UPDate
CALCulate:LLINe[1]|2|…|6:OFFSet:X
CALCulate:LLINe[1]|2|…|6:OFFSet:Y
CALCulate:LLINe[1]|2|…|6:TRACe
CALCulate:LLINe[1]|2|…|6:TYPE
CALCulate:LLINe:ALL:DELete
CALCulate:LLINe:CONTrol:DOMain
CALCulate:LLINe:TEST
CALCulate:MAMarker:COUPling
CALCulate:MAMarker:DETector[1]|2|3
CALCulate:MAMarker:DETector[1]|2|3:DWELl
CALCulate:MAMarker:PCENter
CALCulate:MARKer[1]|2|…|24:CPSearch[:STATe]
CALCulate:MARKer[1]|2|…|24:FCOunt:GATetime
CALCulate:MARKer[1]|2|…|24:FCOunt:GATetime:AUTO
CALCulate:MARKer[1]|2|…|24:FCOunt[:STATe]
CALCulate:MARKer[1]|2|…|24:FCOunt:X?
CALCulate:MARKer[1]|2|…|24:FUNCtion
CALCulate:MARKer[1]|2|…|24:FUNCtion:BAND:LEFT
CALCulate:MARKer[1]|2|…|24:FUNCtion:BAND:RIGHt
CALCulate:MARKer[1]|2|…|24:FUNCtion:BAND:SPAN
2707 Spectrum Analyzer Mode User's &Programmer's Reference

Table of Contents

Other manuals for Keysight x-series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight x-series and is the answer not in the manual?

Keysight x-series Specifications

General IconGeneral
Analysis BandwidthUp to 1 GHz (depending on model)
Real-Time BandwidthUp to 1 GHz (depending on model)
Form FactorBenchtop
ConnectivityLAN, USB, GPIB
Resolution Bandwidth1 Hz to 10 MHz (depending on model)

Related product manuals