Status-indicator-raps
005-309 Left Hand Interlock Open while Running
Left Hand Interlock Open during DADF operation detected.
Procedure
To check the Dynamic Jam occurrence frequency and clear the problem Jam. Check the con-
nections between the L/H Interlock Switch and the DADF PWB. If OK, replace the L/H Interlock
Switch. If the problem persists, replace the DADF PWB (PL 16.3).
005-900 No Belt DADF Applicable Sensor Static Jam
Interlock Open during DADF operation.
Procedure
If the problem occurs frequently, to check Top Cover Latch. Check the connections between
the Top Cover Interlock Switch and the DADF PWB. If OK, replace the Top Cover Interlock
Switch. If the problem persists, replace the DADF PWB (PL 16.3).