January 2007
2-755
WorkCentre 7132
116-341, 116-342
Status-indicator-raps
Revision
116-341 ROM Version RAP
• Multiple incorrect versions of the ROM DIMM are installed.
• An invalid combination of ROM DIMMs are installed.
Initial Actions
Power Off/On
Procedure
NOTE: When installing multiple ROM DIMMs, it is necessary to match both the major versions
and the minor versions.
Check the version of the ROM DIMM and if necessary, replace it with the correct version of the
DIMM (PL 11.2).
116-342 Network Manager RAP
An internal shutdown occurred due to an error in processing SNMP (Simple Network Manage-
ment Protocol).
Initial Actions
Power Off/On
Procedure
Reload Software (ADJ 9.3.1).