123-379 Dispatch RAP
The UI software failed.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).
123-380 Copy Interface RAP
The UI software failed.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).