January 2007
2-756
WorkCentre 7132
116-343, 116-346
Revision
Status-indicator-raps
116-343 Main PWB IC RAP
An error is detected in the IC in the ESS PWB.
Initial Actions
Power Off/On
Procedure
Check the connection of each ESS PWB connector. The connectors are securely con-
nected.
YN
Connect the connectors.
Switch on the power again. The problem persists.
YN
Return to Service Call Procedures.
Replace the ESS PWB (PL 11.2).
116-346 Formatter RAP
Errors are detected by the Formatter.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists, replace the ESS PWB (PL 11.2).