January 2007
2-724
WorkCentre 7132
093-425, 093-912
Revision
Status-indicator-raps
093-425 C Toner Near Empty
Cyan Toner Cartridge is near empty
Procedure
Check the following:
• Replace the Cyan Toner Cartridge if empty (PL 5.2)
• That the Cyan Toner Cartridge is inserted properly
• For Cyan Toner spills in the machine
093-912 Black Toner Empty
Black Toner Cartridge is Empty.
Initial Actions
Check the following:
• Replace the Black Toner Cartridge if empty (PL 5.2)
• Ensure that the Black Toner Cartridge is inserted properly
• For Black Toner spills in the machine
Procedure
Check for Image Quality Defects. An Image Quality Defect is present.
YN
Run ProCon On (ADJ 9.1.10) and follow the Corrective Actions.
The Defect is Low Image Density or Uneven Density.
YN
The Defect is Background.
YN
Run ProCon On (ADJ 9.1.10) and follow the Corrective Actions.
Go to IQ6 and troubleshoot IOT Background.
Go to IQ3 and troubleshoot Low Image Density or Uneven Density.