EasyManuals Logo

Xerox WorkCentre 7132 Service Documentation

Xerox WorkCentre 7132
1726 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #850 background imageLoading...
Page #850 background image
January 2007
2-817
WorkCentre 7132
123-371 , 123-372
Status-indicator-raps
Revision
123-371 Interface Parameter RAP
There is an error in the parameter sent from the Controller.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the ESS PWB (PL 11.2).
123-372 Interface Sequence RAP
The initialization command from the Controller was not sent within the specified time.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the ESS PWB (PL 11.2).