Page #843 background image
January 2007
2-810
WorkCentre 7132
123-332, 123-333
Revision
Status-indicator-raps
123-332 Interface Parameter RAP
The UI software failed and an incorrect parameter was received by the DM-CP driver interface.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).
123-333 Interface Communication RAP
The system detected that transmission with the Control Panel could not be established.
The H/W connection in the UI is faulty and the internal connection isn’t detected.
Initial Actions
Power Off/On
Procedure
Disconnect and reconnect the electrical connections on the UI PWB (PL 13.2) and P/J388 on
the ESS PWB (PL 11.2)
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists replace the UI PWB (PL 13.2).
If the problem persists replace the ESS PWB (PL 11.2).

Table of Contents

Other manuals for Xerox WorkCentre 7132

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox WorkCentre 7132 and is the answer not in the manual?

Xerox WorkCentre 7132 Specifications

General IconGeneral
BrandXerox
ModelWorkCentre 7132
CategoryAll in One Printer
LanguageEnglish

Related product manuals