January 2007
2-685
WorkCentre 7132
077-314, 077-602
Status-indicator-raps
Revision
077-314 Tray Module Logic RAP
BSD-ON:3.3
There is a Tray Module logic failure.
Procedure
Perform the following
Switch the power off, disconnect and reconnect P/J541 on the Tray Module PWB, then
on the power.
Check the circuits between P/J125 on the MCU PWB and P/J541 (2TM) or P/J541
(TTM) on the Tray Module PWB (Flag 5, Flag 6) for an open circuit or short circuit failure.
Repair as required.
Perform ADJ 9.3.1 Software Loading and Upgrading.
077-602 OHP Sensor RAP
BSD-ON:8.7
A description is not available at time of publication
Procedure
A procedure is not available at time of publication.