WorkCentre 7132
005-909, 005-910
Status-indicator-raps
Revision
005-909 DADF Lead Sensor Static Jam
Lead Reg Sensor On detected at the timing below:
1. Power On
2. Feeder Cover Interlock Close
3. Platen Interlock Close.
Procedure
If the problem occurs frequently, make sure that there is no obstacle blocking the light path on
Lead Reg Sensor. Check the connections between the Lead Reg Sensor and the DADF PWB.
If OK, replace the Lead Reg Sensor. If the problem persists, replace the DADF PWB (PL 16.3).
005-910 DADF Out Sensor Static Jam
Out Sensor On detected at the timing below:
1. Power On
2. Feeder Cover Interlock Close
3. Platen Interlock Close.
Procedure
If the problem occurs frequently, make sure that there is no obstacle blocking the light path on
Out Sensor. Check the connections between the Out Sensor and the DADF PWB. If OK,
replace the Out Sensor. If the problem persists, replace the DADF PWB (PL 16.3).