January 2007
2-164
WorkCentre 7132
012-902, 012-903
Revision
Status-indicator-raps
012-902 H-Transport Exit Sensor RAP
BSD-ON:12.2
Paper remains on the H-Transport Exit Sensor.
Initial Actions
• Remove foreign substances on the sensor.
• Power Off/On
Procedure
Execute Component Control[012-191 H-Transport Exit Sensor]. Actuate the H-Transport Exit
Sensor (PL 16.3with paper.
The display changes.
YN
Check the connections of P/J8381 and P/J8390. P/J8381 and P/J8390 are con-
nected correctly.
YN
Connect P/J8381 and P/J8390.
Check the wire between J8381 and J8390 for an open circuit or a short circuit (BSD 12.2
Flag 3/Flag 4).
The wire between J8381 and J8390 is conducting without an open
circuit or a short circuit.
YN
Repair the open circuit or short circuit.
Measure the voltage between the Finisher PWB P8390-6 (+) and GND (-) (BSD 12.2 Flag
4).
The voltage is approx. +5VDC.
YN
Replace the Finisher PWB (PL 17.12).
Measure the voltage between the Finisher PWB P8390-14 (+) and GND (-) (BSD 12.2
Flag 3).
Actuate the H-Transport Exit Sensor with paper. The voltage changes.
YN
Replace the H-Transport Exit Sensor (PL 17.3).
Replace the Finisher PWB (PL 17.12).
Replace the Finisher PWB (PL 17.12).
012-903 Paper Remains at Compiler Entrance Sensor RAP
BSD-ON:12.3
Paper remains on the Compiler Entrance Sensor.
Initial Actions
• Remove foreign substances on the sensor.
• Power Off/On
Procedure
Execute Component Control [012-150 Compile Entrance Sensor]. Actuate the Compiler
Entrance Sensor with paper.
The display changes.
YN
Check the connections of P/J8814, P/J8825 and P/J8850. P/J8814, P/J8825 and P/
J8850 are connected correctly.
YN
Connect P/J8814, P/J8825 and P/J8850.
Check the wire between J8814 and J8850 for an open circuit or a short circuit (BSD 12.3
Flag 1/Flag 2).
The wire between J8814 and J8850 is conducting without an open
circuit or a short circuit.
YN
Repair the open circuit or short circuit.
Measure the voltage between the Finisher PWB P8850-B9 (+) and GND (-) (BSD 12.3
Flag 2).
The voltage is approx. +5VDC.
YN
Replace the Finisher PWB (PL 17.12).
Measure the voltage between the Finisher PWB P8850-B8 (+) and GND (-) (BSD 12.3
Flag 1).Actuate the Compiler Entrance Sensor with paper.
The voltage changes.
YN
Replace the Compiler Entrance Sensor (PL 17.11).
Replace the Finisher PWB (PL 17.12).
Replace the Finisher PWB (PL 17.12).

Table of Contents

Other manuals for Xerox WorkCentre 7132

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox WorkCentre 7132 and is the answer not in the manual?

Xerox WorkCentre 7132 Specifications

General IconGeneral
BrandXerox
ModelWorkCentre 7132
CategoryAll in One Printer
LanguageEnglish

Related product manuals