January 2007
2-318
WorkCentre 7132
024-373, 024-375
Revision
Status-indicator-raps
024-373 IOT-ESS Communication 23 RAP
BSD-ON:3.1/16.1
In response to a message packet from the Controller, the acknowledgement packet was not
received within the specified time even after the specified number of attempts.
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists, reload Software (ADJ 9.3.1).
If the problem persists, replace the MCU PWB (PL 11.1) If the problem persists, replace the
ESS PWB (PL 11.2).
024-375 IOT-ESS Communication 24 RAP
BSD-ON:3.1/16.1
An illegal instruction for IOT Port number or time-out timing or for the pointer or for transfer size
was detected.
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists, reload Software (ADJ 9.3.1).