WorkCentre 7132
003-346, 003-750
Status-indicator-raps
Revision
003-346 PIO Unlatched 2 RAP
BSD-ON:3.1/6.2
When IIT image was received from the IIT/IPS PWB, a PIO (Programmed Input/Output) error
was detected.
Procedure
Disconnect and reconnect the IIT/IPS PWB Harness.
If the problem persists replace the IIT/IPS PWB (PL 13.3).
If the problem persists replace the ESS PWB (PL 11.2).
003-750 Book Duplex Documents RAP
Book duplex is not set up with the correct number of documents.
Procedure
Ask customer to check the Book Duplex setup menu.