January 2007
2-476
WorkCentre 7132
034-782, 034-783
Revision
Status-indicator-raps
034-782 Fax Communication RAP
An error cleared due to time-out.
Procedure
Ask customer to cancel the job and resend.
034-783 Fax Communication RAP
An unspecified protocol error occurred.
Procedure
Check the Fax line connection (telephone line).
If the problem persists check the connections on the FCB PWB.
If the problem persists perform GP 2 Fax Checkout.
If the problem persists replace the FCB PWB (PL 11.3).