Status-indicator-raps
116-375 Formatter RAP
A response such as system function recall error is detected.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).
116-376 Port 9100 Software RAP
An internal shutdown occurred after a processing error.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).