January 2007
2-309
WorkCentre 7132
024-345, 024-346
Status-indicator-raps
Revision
024-345 IOT-ESS Communication 5 RAP
BSD-ON:3.1
A transmission failure occurred when the Check Code of the sent Message Packet is incorrect.
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).
024-346 IOT-ESS Communication 6 RAP
BSD-ON:3.1
A transmission failure occurred, a parity error was detected by hardware in the IOT.
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).