January 2007
2-729
WorkCentre 7132
093-951, 093-952
Status-indicator-raps
Revision
093-951 Toner M CRUM Data Broken Failure
BSD-ON:9.1
M Toner CRUM Data Broken Failure.
Initial Actions
• Ensure that the Magenta Toner Cartridge is seated correctly.
• Ensure that the Toner Cartridge Door is closed.
Procedure
Fault codes 093-925 (K), 093-950 (Y), and 093-952 (C) are also present on the UI.
YN
Replace the Magenta Toner Cartridge (PL 5.2).
Replace the Toner CRUM (Toner Cartridge Door) (PL 5.1).
If the fault codes are still present, replace the MCU PWB (PL 11.1).
093-952 Toner C CRUM Data Broken Failure
BSD-ON:9.1
C Toner CRUM Data Broken Failure.
Initial Actions
• Ensure that the Cyan Toner Cartridge is seated correctly.
• Ensure that the Toner Cartridge Door is closed.
Procedure
Fault codes 093-925 (K), 093-950 (Y), and 093-951 (M) are also present on the UI.
YN
Replace the Cyan Toner Cartridge (PL 5.2).
Replace the Toner CRUM (Toner Cartridge Door) (PL 5.1).
If the fault codes are still present, replace the MCU PWB (PL 11.1).