January 2007
2-456
WorkCentre 7132
034-742, 034-743
Revision
Status-indicator-raps
034-742 Fax Communication RAP
BSD-ON:16.1/17.1
A frame send error is detected.
Procedure
Check the Fax line connection (telephone line).
If the problem persists check the connections on the FCB PWB.
If the problem persists perform GP 2 Fax Checkout.
If the problem persists replace the FCB PWB (PL 11.3).
034-743 Fax Communication RAP
BSD-ON:16.1/17.1
When sending frames, the DMA (Dynamic Memory Access) was abnormally terminated.
Procedure
Check the Fax line connection (telephone line).
If the problem persists check the connections on the FCB PWB.
If the problem persists replace the FCB PWB (PL 11.3).