January 2007
2-311
WorkCentre 7132
024-349, 024-350
Status-indicator-raps
Revision
024-349 IOT-ESS Communication 9 RAP
BSD-ON:3.1
A transmission failure occurred as the acknowledgement could not be received after 2 resend
attempts. (After header recognition, receive interruption was detected by the IOT.)
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).
024-350 IOT-ESS Communication 10 RAP
BSD-ON:3.1
The NAK that notifies of the occurrence of a transmission failure is received. (The Sequencing
number of the received Message Packet is incorrect.)
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).