January 2007
2-307
WorkCentre 7132
024-340, 024-341
Status-indicator-raps
Revision
024-340 IOT-ESS Communication 1 RAP
BSD-ON:3.1/16.1
An abnormal parameter is set for the send function.
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists, reload Software (ADJ 9.3.1).
024-341 IOT-ESS Communication 2 RAP
BSD-ON:3.1/16.1
A transmission failure occurred, the Sequencing number of the sent Message Packet is incor-
rect.
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the MCU PWB (PL 11.1).