January 2007
2-757
WorkCentre 7132
116-348, 116-349
Status-indicator-raps
Revision
116-348 Redirector RAP
A system function recall error is detected by the Redirector.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists, replace the ESS PWB (PL 11.2).
116-349 SIF RAP
An error occurred using the SIF (Source Input Format) function.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists reload Software (ADJ 9.3.1).
If the problem persists, replace the ESS PWB (PL 11.2).