January 2007
2-452
WorkCentre 7132
034-733, 034-735
Revision
Status-indicator-raps
034-733 Fax Communication RAP
BSD-ON:16.1/17/1
There is a sequence error or message incompatibility.
Procedure
Check the Fax line connection (telephone line).
If the problem persists check the connections on the FCB PWB.
If the problem persists perform GP 2 Fax Checkout.
If the problem persists replace the FCB PWB (PL 11.3).
034-735 Fax Communication RAP
The connection is limited to D channel.
Procedure
Ask customer to cancel the job and resend.