Status-indicator-raps
024-342 IOT-ESS Communication 3 RAP
BSD-ON:3.1
A transmission failure occurred, the Packet number of the sent Message Packet is incorrect.
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).
024-343 IOT-ESS Communication 4 RAP
BSD-ON:3.1
A transmission failure occurred, the Message Length of the sent Message Packet is incorrect.
Initial Actions
Power Off/On
Procedure
Check that P/Js 402 on the MCU PWB (PL 11.1) and P/J 310 on the ESS PWB (PL 11.2) are
securely connected.
If the problem persists reload Software (ADJ 9.3.1).