092-649 ADC Shutter Open RAP
BSD-ON:9.4A
The ADC Shutter failed to open.
Procedure
Remove the Sensor Bar Assembly (PL 11.1). Check the operation of the shutter. If the shutter
cannot be repaired, replace the Sensor Bar Assembly (PL 11.1).
092-650 ADC Shutter Close RAP
BSD-ON:9.4A
The ADC Shutter failed to close.
Procedure
Remove the Sensor Bar Assembly (PL 11.1). Check the operation of the shutter. If the shutter
cannot be repaired, replace the Sensor Bar Assembly (PL 11.1).