WorkCentre 7132
116-364, 116-365
Status-indicator-raps
Revision
116-364 Timer RAP
A timer failure is detected in the ESS PWB.
Initial Actions
Power Off/On
Procedure
Check the connection of each ESS PWB connector. The connectors are correctly con-
nected.
YN
Connect the connectors.
Turn on the power again. The problem persists.
YN
Return to Service Call Procedures.
Replace the ESS PWB (PL 11.2).
116-365 Spool RAP
An internal shutdown occurred after an SPL processing error.
Initial Actions
Power Off/On
Procedure
Pull out and insert or replace the DIMM (PL 11.2).
If the problem persists perform Hard Disk Diagnostic Program.
If the problem persists replace the HDD (PL 11.2).