January 2007
6-119
WorkCentre 7132
Controller & Fax NVM List
General procedures information
Reversion 4.0
790-051 Pre Set Tray 2 0~255 2: Tray 2 Read/
Write
0: None (not in use), 1: Tray 1, 2: Tray 2, 3: Tray 3, 4: Tray 4, 5:6: HCF1,SMH,7: HCF2
790-052 Pre Set Tray 3 0~255 3: Tray 3 
(HBUI), 5: 
SMH (FCWUI)
Read/
Write
0: None (not in use), 1: Tray 1, 2: Tray 2, 3: Tray 3, 4: Tray 4, 5: SMH,6: HCF1,7: HCF2
790-060 R/E Preset 1 0~12 2: R/E Preset 2 Read/
Write
0: None, 1~12: R/E Preset 1 to R/E Preset 12
790-061 R/E Preset 2 0~12 7: R/E Preset 7 Read/
Write
0: None, 1~12: R/E Preset 1 to R/E Preset 12
790-070 Default Tray Setting in Copy 
Mode
0~5 0: Auto Read/
Write
0: Auto, 1: Tray 1, 2: Tray 2, 3: Tray 3, 4: Tray 4, 5: SMH
790-071 Tray at Auto Cancellation 0~12 1: Tray 1 Read/
Write
1: Tray 1, 2: Tray 2, 3: Tray 3, 4: Tray 4
790-072 Default R/E Setting in Copy 
Mode
0~255 0: 100% Read/
Write
0: 100%, 1~12: R/E Preset 1 to R/E Preset 12, 255: Auto
790-073 R/E Preset 1 Setting 25~1025 1003: 50.00% Read/
Write
1~24: Not in use, 25~400:%, 401~1000: Not in use, 1001: 25.00%, 1002: 35.30%, 1003: 50.00%, 1004: 
57.70%, 1005: 61.20%, 1006:64.70%, 1007: 70.70%, 1008: 78.50%, 1009: 81.60%, 1010: 86.60%, 
1011: 94.00%, 1012: 97.30%, 1013: 115.40%, 1014: 122.50%, 1015: 127.30%, 1016: 129.40%, 1017: 
141.40%, 1018: 154.50%, 1019: 163.20%, 1020: 173.20%, 1021: 180.00%, 1022: 200.00%, 1023: 
220.00%, 1024: 282.80%, 1025: 400.00%
790-074 R/E Preset 2 Setting 1001~1025 1007: 70.70% Read/
Write
1~1000: Not in use,1001: 25.00%, 1002: 35.30%, 1003: 50.00%, 1004: 57.70%, 1005: 61.20%, 1006: 
64.70%, 1007: 70.70%, 1008: 78.50%, 1009: 81.60%, 1010: 86.60%, 1011: 94.00%, 1012: 97.30%, 
1013: 115.40%, 1014: 122.50%, 1015: 127.30%, 1016: 129.40%, 1017: 141.40%, 1018: 154.50%, 
1019: 163.20%, 1020: 173.20%, 1021: 180.00%, 1022: 200.00%, 1023: 220.00%, 1024: 282.80%, 
1025: 400.00%
790-075 R/E Preset 3 Setting 1001~1025 1009: 81.60% Read/
Write
ditto
790-076 R/E Preset 4 Setting 1001~1025 1010: 86.60% Read/
Write
ditto
790-077 R/E Preset 5 Setting 1001~1025 1013: 115.40% Read/
Write
ditto
790-078 R/E Preset 6 Setting 1001~1025 1014: 122.50% Read/
Write
ditto
790-079 R/E Preset 7 Setting 1001~1025 1017: 141.40% Read/
Write
ditto
790-089 Default Extracted Color for Dual 
Color
1~255 1: Except 
Black
Read/
Write
1 (0x01): Except Black, 2 (0x02): Red, 4 (0x04): Green, 8 (0x08): Blue,  
16 (0x10): Yellow (Y), 32 (0x20): Magenta (M), 64 (0x40): Cyan (C)
790-090 Default Color Mode 0~5 2: BW Read/
Write
0: None, 1: Auto, 2: BW, 3: 4 Color, 4: Single Color, 5: Dual Color
790-091 Default Single Color Selection 1~12 1: Custom 
Color 1
Read/
Write
1~6: Preset Color 1 to Preset Color 6, 7~12: Custom Color 1 to Custom Color 6
790-092 Reproduction Color Selection 
Default except for Extracted 
Part
0~12 0: Black Read/
Write
0: Black, 1~6: Preset Color 1 to Preset Color 6, 7~12: Custom Color 1 to Custom Color 6
Table 8  UI
Chain-Link NVM Name
Setup 
Range Initial Value
Read/
Write Description