January 2007
6-124
WorkCentre 7132
Controller & Fax NVM List
Reversion 4.0
General procedures information
790-214 Fixed Size 5 of FAX Scan Size
Input
1~255 16: A6 SEF Read/
Write
ditto
790-215 Fixed Size 6 of FAX Scan Size
Input
1~255 66: B4 SEF Read/
Write
ditto
790-216 Fixed Size 7 of FAX Scan Size
Input
1~255 68: B5 SEF Read/
Write
ditto
790-217 Fixed Size 8 of FAX Scan Size
Input
1~255 67: B5 LEF Read/
Write
ditto
790-218 Fixed Size 9 of FAX Scan Size
Input
1~255 80: 11x17 SEF Read/
Write
ditto
790-219 Fixed Size 10 of FAX Scan Size
Input
1~255 90: 8.5x11
SEF
Read/
Write
ditto
790-220 Fixed Size 11 of FAX Scan Size
Input
1~255 89: 8.5x11 LEF Read/
Write
ditto
790-221 Default FAX Profile 1~2 0:TIFF-S Read/
Write
0: TIFF-S, 1: TIFF-F, 2: TIFF-J
790-222 Default Mixed Size 0~1 0: OFF Read/
Write
0: OFF, 1: ON
790-223 Default Color Mode 0~3 2: B/W Binary Read/
Write
0: Full Color, 1: Grayscale, 2: B/W Binary, 3: Auto
790-224 Default Document Type 0~2 0: Text Read/
Write
0: Text, 1: Text/Photo, 2: Photo
790-225 Default Resolution 0~4 0: 200dpi Read/
Write
0: 200dpi, 1: 300dpi, 2: 400dpi, 3: 600dpi, TBD: 100dpi
790-226 Default Top and Bottom Edge
Erase
0~50 2 (mm) Read/
Write
1mm unit from 0 (mm) to 50 (mm)
790-227 Default Left and Right Edge
Erase
0~50 2 (mm) Read/
Write
1mm unit from 0 (mm) to 50 (mm)
790-228 Default Center Erase 0~50 0 (mm) Read/
Write
1mm unit from 0 (mm) to 50 (mm)
790-229 Default Density/Brightness
Adjustment (Using data com
-
mon to Density, Brightness)
0~6 3: Standard Read/
Write
0: Brightness (Density) 3, 1: Brightness (Density) 2, 2: Brightness (Density) 1, 3: Standard, 4: Bright-
ness (Density) -1, 5: Brightness (Density) -2, 6: Brightness (Density) -3
790-230 Default Contrast Adjustment 0~4 2: Standard Read/
Write
0: Stronger 2, 1: Stronger 1, 2: Standard, 3: Softer 1, 4: Softer 2
Table 8 UI
Chain-Link NVM Name
Setup
Range Initial Value
Read/
Write Description